pxie-5160. NI System Configuration: - NI PXIe-1071, 4-Slot 3U PXI Express Chassis , 1 GB/Slot throughput, Part Number: 781368-01 - NI PXIe-PCIe8381,x8 Gen2 MXI-Express for PXI Express Interface,3m, Part Number: 782522-01 - PXIe-5160 PXI Oscilloscope, 500 MHz, 10 bits, 2. pxie-5160

 
NI System Configuration: - NI PXIe-1071, 4-Slot 3U PXI Express Chassis , 1 GB/Slot throughput, Part Number: 781368-01 - NI PXIe-PCIe8381,x8 Gen2 MXI-Express for PXI Express Interface,3m, Part Number: 782522-01 - PXIe-5160 PXI Oscilloscope, 500 MHz, 10 bits, 2pxie-5160  Buy 782621-03 - Ni - PXIE-5160 PXI OSCILLOSCOPE, 500 MHZ, 10 BITS, 2

Free shipping. +1 800. Trusted Enthusiast. Programming the PXIe-5160/5162. The NI SA1000X is launched with the part number 784255-01. 5 GS/s I have PXIe-5160 PXI Oscilloscope, 500 MHz, 10 bits, 2. 75 bath property. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Place the module edges into the module guides at the. Manufacturer: National Instruments Model: PXIE PXIe-5160, 500 MHz, 2 or 4 Channel, PXI Oscilloscope National Instruments PXIe-5160 High-Speed DigitizerThe PXIe-5160 (Part Numbers: 782621-01, 782621-02, 782621-03, 155377A-22L) Digitizer has three activation so. The photomultiplier tube signal was sampled at 625 MS s −1 with a high-speed digitizer (2G onboard memory, PXIe-5160, National Instruments) embedded in a chassis (PXIe-1071, National Instruments. Goodman on LinkedIn: PXIe-5160 From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 5 GS/s or 5 GS/s, 10-Bit PXI Oscilloscopes Note Before you begin, install and configure your chassis and controller. Buy 782621-01 - Ni - PXIE-5160 PXI OSCILLOSCOPE, 500 MHZ, 10 BITS, 2. Math Functions for NI-Scope. View and Download National Instruments PXIe-5172 getting started manual online. NI System Configuration: - NI PXIe-1071, 4-Slot 3U PXI Express Chassis , 1 GB/Slot throughput, Part Number: 781368-01 - NI PXIe-PCIe8381,x8 Gen2 MXI-Express for PXI Express Interface,3m, Part Number: 782522-01 - PXIe-5160 PXI Oscilloscope, 500 MHz, 10 bits, 2. 1, which has 24-bit ADC resolution, allows 51,200 samplings per second, whereas system No. com Board Assembly Part Number(s) Part Number Description 154213x-01L MODULE ASSEMBLY, PXIE-5162, OEM 154772x -21L MODULE ASSEMBLY, PXIE 5162, 2CH, 64MB 157772A-22L 157772x-22L. 08 m SMB-100 (part number 781449-01). The PXIe‑5122 high-resolution PXI oscilloscope has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. PXIe, 500 MHz, 2. 5 GS/s with flexible settings for coupling, voltage range, and filtering. Pxie, 200 mhz, 1 gs/s, 14-bit pxi oscilloscope (22 pages)This page documents all the applicable standards and certifications for the PXIe-5160 and provides downloadable certifications. Test Equipment National Instruments PXIe-5160 Getting Started Manual. 7. This home was built in 1991 and last sold on. <LabVIEW>[email protected] V 0. This board has an onboard 10 MHz TCXO that can be disciplined to an external time reference such as GPS, IEEE 1588, or IRIG-B. Call. We have a PXIe-1095 chassis that houses an NI PXIe-8880 controller, PXIe-4080 DMM, PXIe-5160 Oscilloscope, and 15 other PXIe modules. - NI PXIe-PCIe8381,x8 Gen2 MXI-Express for PXI Express Interface,3m, Part Number: 782522-01. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. Connect the external signal to all digitizers. The PXIe-5160 is a 500 MHz, 10-bit oscilloscope with a sample rate of up t… NI-SCOPE is loaded and recognizes the PXIe-5160. Minimum order of 1 items Multiples of 1 only Please enter a valid quantity. NI™ manufactures high-speed digitizers and oscilloscopes that use the NI-SCOPE driver. 5 GS/s, 10-Bit PXI Oscilloscope. System No. PXIe,500 MHz,2. PXIe-5110/5111/5113 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. Place the module edges into the module guides at the. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。NI-SCOPE is loaded and recognizes the PXIe-5162. Test Equipment National Instruments PXIe-5160 Getting Started Manual. Acquires and analyzes time- and frequency‐domain analog signals as part of a PXI system. Documentation for the PXIe-5160/5162 is available from the Start menu by navigating to NI-SCOPE Documentation in the National Instruments folder. Connector. From this location the cards within the PXI (e) Chassis can use the signal which comes through the trigger line. com amE il: sela s@a mpli con. 6. These procedures are valid for NI-SCOPE devices, EXCEPT the PXIe-5160/5162 and PXIe-5185/5186. PXIe-5160 Dimensional Drawings This page provides dimensional drawings for the PXIe-5160. National Instruments produces the SA1000X probe. If I want to continuously acquire data at full sampling rate for just a single channel i. PFI 1. Add. VPC designs, manufactures and markets interconnect solution products for a variety of industries including automotive, aerospace, new space, defense, medical, telecommunication, and more. National Instruments PXIe-5160 High-Speed Digitizer. Farnell Ireland offers fast quotes, same day dispatch, fast delivery, wide inventory, datasheets & technical support. 5 GS/s with flexible settings for coupling, voltage range, and filtering. Account & Lists. Module. $11,092. Test Equipment National Instruments PXIe-5160 Getting Started Manual. PXIe, 500 MHz, 2. I have PXIe-5160 PXI Oscilloscope, 500 MHz, 10 bits, 2. NI-DAQmx. 2 has four times' higher sampling rate capacity than that of system No. Delivering to Lebanon 66952 Update location Electronics. Note InstrumentStudio is supported only on 64-bit systems. Search. 8. NI 9237 Letter of Volatility. Touch any metal part of the chassis to discharge static electricity. 1553. National Instruments Model PXIe-5160 National Instruments PXIe-5160 National Instruments PXIe-5160. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. 5 GS/s,10-Bit PXI Oscilloscope at the best online prices at eBay! Free shipping for many products!PXIE-5160 Controller module, NI, PXIE-5160 Controller module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. NI provides the necessary software for your PXI or PXIe (PXI Express) controller and chassis. 5 GS/s, 2 channels, 64 MB – dataTec Onlineshop. Table of Contents. All Forum Topics;09-30-2021 10:45 AM. Test & Measurement-Information Technology-Laboratory Equipment-Medical Equipment. NI PXIe-5160 (782621-03) Datasheet Datasheet 248. 至少每六个月清理一次机箱风扇过滤器(如果合适)。. When monitoring a station’s connectivity, you should check for cable differences, which can be detected at distances smaller than the spatial resolution might suggest. 1. Manufacturer Part No: 782991-01. com: National Instruments, NI, NI PXIE-5160 : Electronics. Touch any metal part of the chassis to discharge static electricity. Open FPGA for custom real-time signal processing requires DEVDAQ. 5 GHz 10ビットオシ ロスコープです。 PXIe-5160/5162のドキュメントは、スタートメニューからNational InstrumentsフォルNI-SCOPE 4. 6. 5 GS/s high-speed digitizer; NI-P2P support for the NI PXIe-5160 and the NI PXIe-5162; NI-SCOPE 4. PXIe-5160/5162 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. For more155377x-22L MODULE ASSEMBLY, PXIE-5160, 2CH, 2GB 155377x-42L MODULE ASSEMBLY, PXIE-5160, 4CH, 2GB Volatile Memory Target Data Type Size Battery Backup User1 Accessible System Accessible Sanitization Procedure Waveform Data Synchronous DRAM 64 MB, or 2 GB No Yes Yes Cycle Power DRAM Buffers FPGA Altera EP3SL150. NI 9237 Letter of Volatility. Quick View. PXIe-5160 / 782621-02 - NI. Get support on a product. 5 ghz, 2. M3202A. 65 KB We offer many of our products to test drive in your specific application, simply fill in the short form below, one of our technical application engineers will call you. Note that Windows 32-bit and 64-bit support is dependent upon. Here, you can click the Chassis tab and select the PXI Express Chassis you are interested in purchasing. 5 GS/s, 2 Channels, 64 MB, Part Number: 782621-01 - Astronics PXIe. System No. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. 5 GS/s, 10-Bit PXI Oscilloscope—The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. Manufacturer: NI. This document explains how to install, configure, and test the PXIe-5163. Log in. Control Unit I/O Systems Controller Measuring Instruments. Farnell Ireland offers fast quotes, same day dispatch, fast delivery, wide inventory, datasheets & technical support. For the PXIe-5160/5162, self-calibration yields the following benefits: Corrects for DC gain and offset errors within the digitizer by comparison to a precision, high-stability internal voltage reference for all ranges, input impedance paths (50 Ω and 1 MΩ), and filter paths. It uses the NI-Scope driver softwares not the NI-DAQmx driver software. In a DAQ Assistant Express VI, you can configure this on the Configuration tab in Timing Settings >> Rate (Hz). 7 GHz RF Vector Signal Generator. The PXIe-5160 is a 500 MHz, 10-bit oscilloscope with a sample rate of up to 2. 5 GS/s with flexible settings for coupling, voltage range, and filtering. com, and the Help files install with the software. 2. Buy 782621-02 - Ni - PXIe-5160 PXI Oscilloscope, 500 MHz, 10 bits, 2. 第 1 条消息(共 1 条). The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. Underwood Park,park,5160 Interurban Rd, Victoria, BC V9E 2J6, Canada,address,phone. 5 GSPS, 2 Channels, 64 MB, Cable Sense Technology. National Instruments PXI GPIB Instrument Control Module IEEE 488 controller Test. Place the module edges into the module guides at the. 7. 下一个主题. PXIe-5160. 7. 5 GS/s, 2 channel, 10 bit input resolution and a 2 GB on-board memory. Now, when you go to the Modules tab, you will notice that the incompatible cards are grayed out. PXIe-5114: National Instruments PXIe-5114- 16, 128, or 512 MB onboard memory: In Stock Ships in 5-10 Days: PXIe-5122: National Instruments PXIe-5122- 8, 64, or 256 MB/channel onboard memory: In Stock Ships Today: PXIe-5160: National Instruments PXIe-5160- 2. 768 次查看. Table 1. PXIe-5105 60 MHz 60 MS/s 12 bits, 8 channels PXIe-5160 500 MHz 2. 5 GS/s, 10-Bit PXI Oscilloscope—The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. Original Ni PXIE-5160 782621-01 PXIE 5160 high speed oscilloscope equipment. You can reference the PFI connector with the terminal name / [hostname]/PFI n where [hostname] is the. NI 5105 Specifications Contains: NI PXI/PXIe/PCI-5105. PXIe-5160/5162 Programming Options. PXIe/PXI/PCI-51051 PFI 1 PXI/PCI-5152 PFI 1 PXIe-5160 PFI 1 PXIe-5162 PFI 1 PXIe-5163 SMB PFI 02 PXIe-5164 SMB PFI 02 1 Requires a probe capable of compensating high capacitance inputs and a BNC (f)-to-SMB (f) cable with sufficiently low capacitance, such as the 0. 782621-01 | buy & request To be able to use dataTec en in full range, we recommend activating Javascript in your browser. . arincPXIe-5160은 최대 2. 25 G Amplitude (dBFS) Frequency (Hz) 1 MΩ Spectral Characteristics20 Table 9. 0 项奖励. • Ensure that the PXI chassis fan speed is set to HIGH, that the fan filters (if present) are clean, and that the empty slots contain slot blockers and filler panels. The sampling rate of the data acquisition system with an NI PXIe-5160 oscilloscope was 1. $605. MODULE ASSEMBLY, PXIE-5160, 4CH, 2GB. 8. NI示波器(如PXI-5122或者PXIe-5160)如何在InstrumentStudio上怎么设置成XY-Mode. 5 GS/s with flexible settings for coupling, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. 7. • The PXIe-5160 is warmed up for 15 minutes at ambient temperature • Self-calibration is completed after warm-up period • Calibration cycle is maintained • The PXI Express chassis fan speed is set to HIGH, the foam fan filters are removed if present, and the empty slots contain PXI chassis slot blockers and filler panels. For more information and a list of procedures, refer to the Calibration Executive Help topic DMM Instrument Standard Considerations . Search for used 4 channel oscilloscopes. Start with PXIe-5160 Digital Multimeters • Voltage measurements up to 1,000 VDC • Current measurements up to 3 A • Resistance measurements up to 5 GΩ. Downloads. Provides support for NI data acquisition and signal conditioning devices. Palickar Member 10-22-2020 05:07 PM Options Hello, I have the following hardware: PXI-1085 chasis PXIe-8840 controller Qty (4) PXIe-5160 500mhz Oscilloscope So there are 4. 5 adds support for LabVIEW 2013. 5 GS/s, 2 Channels, 64 MB, Part Number: 782621-01 - Astronics PXIe. PXI Pull-Thru Adapter, Wired, NI PXIe-5160. Refer. This page provides dimensional drawings for the PXIe-5160. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. 5 GS/s, 10-bit PXI Oscilloscope Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. This document explains how to install, configure, and test the NI PXIe-5160/5162 (NI 5160/5162). The PXIe-5162 high-speed oscilloscope device has two or four channels that sample at up to 5 GS/s with flexible settings for coupling, voltage range, and filtering. This site uses cookies to offer you a better browsing experience. You previously purchased this product. Alexa, tell me about the PXIe-5160 from #NI The National Instruments PXIe-5160 is a high-performance, 2 GHz, 2-channel digital oscilloscope. 5 GS/s,10 位PXI示波器—PXIe-5160高速示波器设备具有两个或四个通道,采样速率高达2. 00 £18,480. PXIe-5110 PXIe-5111 PXIe-5113 PXIe-5185 PXIe-5186 50 Ω Bandwidth 100 MHz 350 MHz 500 MHz 3 GHz 5 GHzRe: Change x-axis tick label. 5 GS/s with flexible settings for coupling, voltage range, and filtering. PXI Oscilloscope, PXIe-5160, 500 MHz, 10 bits, 2. The user can compare the input signal in the channel or outside trigger channel to one or two edge thresholds, hysteresis, or window. For more and digitized by a high-speed data acquisition (D AQ) card (10bit, PXIe 5160, NI) at a sampling. 1. 6. 5160 Del Monte Ave , Victoria, BC V8Y1X is currently not for sale. Options. This document contains the verification and adjustment procedures for the PXIe-5160. 6. 5 GS/s, 2 Channels, 2 GB RoHS Compliant: Yes. Fast Quote. The SA1000X is designed to be used with an oscilloscope. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. The NI 5160 is a 500 MHz 10-bit oscilloscope with a sample rate of up to. NI Employee (retired) 10-13-2014 01:36 PM. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. PXIe-5160 500 MHz 2. 5: The following procedures have changed: PXIe-4081 (90 day) PXIe-4081 (2 yr) PXIe-4135; PXIe-4139; PXIe-5840; PXIe-5841; NI 9212; Calibration Executive 6. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data. Signals are triggered measurement channels on one of the NI PXIe-5105, the other two scope cards should synchronized to the trigger signal. Page 2: Verifying The System Requirements (ADEs). NI示波器(如PXI-5122或者PXIe-5160)如何在InstrumentStudio上怎么设置成XY-Mode用来显示李沙育图形?. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data. NATIONAL INSTRUMENTS CORP. Software Support. NI InstrumentStudio 2022 Q1 Readme. 5 GS/s with flexible settings for coupling, voltage range, and filtering. Math Functions for NI-Scope. 0. 2 channels at 5 GSPS or 1 channel at 10 GSPS (software-selectable) Up to 3 GHz input bandwidth. PXIe-5160 or PXIe-5162 3. PXIe-5160 Single Tone Spectrum, 2. 0 Kudos Message 2 of 2 (146 Views) Reply. NI USB-8452 Letter of Volatility. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. 4: Guard band calculation for uncertainties with dB and dBv units has changed. 5 gs/s or 5 gs/s, 10-bit pxi oscilloscopes (18 pages) Test Equipment National Instruments PXIe-5170 Getting Started Manual. 4 Gbyte onboard memory. The NI PXI/PXIe-2532B offers ultrahigh-density switch configurations in PXI/PXIe. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. $1,799. Data is recorded using three National Instruments PXIe-5160 digitizer cards mounted in a PXIe-1073 chassis. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 5 GS/s, 2 Channels, 64 MB, Part Number: 782621-01 - Astronics PXIe. Some procedures require a PXI-4070, PXI-4071, or PXI-4072 DMM as an instrument standard; running these using a PXIe-4080, PXIe-4081, or PXIe-4082 DMM causes errors. 00. PXIe-1488 Letter of Volatility. 1 includes the following new features: Support for the NI PXIe-5160, 2. Hello, sign in. PXIe-5160 Test Equipment Equipment Recommended Model Where Used Minimum Requirements. 782621-01 | PXIe-5160 PXI Oscilloscope, 500 MHz, 10 bits, 2. 155377-42L. 5 GS/s, 10-Bit PXI Oscilloscope—The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. With the addition of these two new PXIe Chassis to the Chassis Family, four chassis are now supported. The warm-up time ensures that the test instruments are at a stable operating temperature. For moreand digitized by a high-speed data acquisition (D AQ) card (10bit, PXIe 5160, NI) at a sampling. An oscilloscope probe is a fundamental part of an analog measurement. 7. 1. Part No. 09-22-2023 04:23 AM. National Instruments has several brands around the world that distributors may use as alternate names. These devices do not support manual calibration, but have mechanisms for adjusting for skew between devices. The The National Instruments PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. 25 GS s −1, and the sample interval was 0. The PXIe‑5105 high-density PXI oscilloscope has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. 5160 Beckton Rd, Victoria, BC V8Y 2C1 is currently not for sale. 2D Dimensional Drawings PDF - 782621-02 PDF - 782621-03 DXF - 782621-02. 5 GS/s with flexible settings for coupling, voltage range, and filtering. 5 GS/s 10 bits, 2/4 channels PXIe-5162 1. 1, GETTING STARTED GUIDE PXIe-5160/5162 PXIe, 500 MHz or 1. The as-found limits are the published specifications for the PXIe-5162. Test Equipment National Instruments PXIe-5160 Getting Started Manual. 2: Fixed an issue causing Traditional NI-DAQ (Legacy) devices to be missing from the NI-SCOPE full installer. Related Documentation. Place the module edges into the module guides at the. The PXIe-5160 is a 500 MHz, 10-bit oscilloscope with a sample rate of up to 2. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. National Instruments PCI-5122, PXIE-5160, PXIE-5162, and PXIE-5622 oscilloscopes for sale. This system could output the measurement results for pulse contrast right after the laser shot, providing fast feedback for laser. PXIe-6570 Firmware and Additional Driversをダウンロードして、サポート情報をご確認ください。このダウンロードページを使用して、PXIe-6570 Firmware and Additional Driversにアクセスできます。また、利用可能なすべてのエディションは、このダウンロードページから入手できます。技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。PXIe/PXI/PCI-51051 PFI 1 PXI/PCI-5152 PFI 1 PXIe-5160 PFI 1 PXIe-5162 PFI 1 PXIe-5163 SMB PFI 02 PXIe-5164 SMB PFI 02 1 Requires a probe capable of compensating high capacitance inputs and a BNC (f)-to-SMB (f) cable with sufficiently low capacitance, such as the 0. 5 GS/s,提供灵活的耦合、电压范围和滤波设置。 PXI示波器还具有多个触发模式、高容量板载内存和一个包含数据流和分析函数的仪器驱动程序。 PXIe, 500 MHz, 2. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。Test Equipment National Instruments PXIe-5160 Getting Started Manual. Re: PXIe-5160 4CH external trigger. Newark offers fast quotes, same day. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 3221366881@qq. 5 GS/s, 10-bit PXI Oscilloscope Read this document and the documents listed in the additional resources section about installation, configuration, and. 1 Hz The ability to measure sine waves ≥10 MHz with我的ni pxie-5160/62 高速数字化仪有2gb的板载存储空间。但是为何我使用板载存储空间大小属性节点时返回的值是2,147,483,647. National Instruments NI VXI-MXI-2 VXI Bus Mainframe Extender 183345D-03. com/calibration for more information about calibration solutions. It offers high channel density and output with low phase noise. Farnell Slovenija offers fast quotes, same day dispatch, fast delivery, wide inventory, datasheets & technical support. Pxie, 500 mhz or 1. EN. 5 GS/s with flexible settings for coupling, voltage range, and filtering. It is an ideal instrument for including in systems for testing devices with I/Q inputs, or as the baseband. PXIE-5160 PXI OSCILLOSCOPE, 500. Calibration Executive 6. 25 V ±5Further, dimensions and details shown in the Models may not reflect the actual dimensions or details of a particular part due to tooling changes, drawing errors or other reasons. PXIe-5122高分解能デジタイザ:PXIe-5122は、チャンネルあたり1回のストリームにつき最大200 MB/sでデータを生成できる100 MS/s、2チャンネルの14ビットデジタイザです。ピアツーピアストリーミング用として、オンボードメモリへの並列データ経路上にライタエンド. The PXIe-5160 has a 10-bit resolution, which gives it 1,024 discrete levels. I have two problems: 1) Unable to route the trigger signal from the measurement channel of the NI PXIe-5105 to the. Buy 782621-03 - Ni - PXIE-5160 PXI OSCILLOSCOPE, 500 MHZ, 10 BITS, 2. However, I am still finding it difficult to understand some concepts of High Speed Digitizer. Ensure that the ejector handle is in the downward (unlatched) position. The PXIe-5171 has a characteristic SFDR of -70 dBc or better, depending on filters, voltage. 5 GS/s with flexible settings for coupling, voltage range, and filtering. NI IMAQ PCI-1405 185816G-02 DAQ DATA ACQUISITION CARD -. For more information on features and programming, refer to the NI High-Speed Digitizers Help . Ensure that the ejector handle is in the downward (unlatched) position. It is a… Jason P. Healthy. 1. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. PXIe-5672 test equipment pdf manual download. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The as-left calibration limits are equal to the published NI specifications for the PXIe-5162,The SA1000X is an Oscilloscope Probe. NI-SCOPE is loaded and recognizes the PXIe-5160. National Instruments Ni Pcie-6341 Multifunction I/o 24 Dio Adapter DAQ Card. A lens group consisting of an axicon lens (AX2510-C, Thorlabs) with a 10° physical angle and a lens with a 125 mm focal length was used. 5 GS/ s, 10 位 PXI 示波器. . 155377x-22L MODULE ASSEMBLY, PXIE-5160, 2CH, 2GB 155377x-42L MODULE ASSEMBLY, PXIE-5160, 4CH, 2GB Volatile Memory Target Data Type Size Battery Backup User1 Accessible System Accessible Sanitization Procedure Waveform Data Synchronous DRAM 64 MB, or 2 GB No Yes Yes Cycle Power DRAM Buffers FPGA Altera EP3SL150. To facilitate the operation of the TC-SSCC device, we developed a data processing system, consisting of an oscilloscope (PXIe-5160, NI) and an analysis software written in LabVIEW, as shown in Figure 6(b). 8. 250. NI provides the necessary software for your PXI or PXIe (PXI Express) controller and chassis. Ensure that the ejector handle is in the downward (unlatched) position. Yes, you can use the PFI0 and PFI1 SMB terminals on the instrument front panel to route external triggers. Each 5160 has 1 channels, 0 and 1. Find used oscilloscopes on Machinio. Nathan-P. 5 GS/s, 2 Channels, 64 MB, Part Number: 782621-01 - Astronics PXIe-1209 2-Channel, 100. • Ensure that the PXI chassis fan speed is set to HIGH, that the fan filters (if present) are clean, and that the empty slots contain slot blockers and filler panels. Pxie, 500 mhz or 1. Download the product flyer of NI oscilloscopes and learn about their features, specifications, and applications. The warm-up time ensures that the PXIe-5162 and test instrumentation are at a stable operating temperature. I have installed LabVIEW 32, chassis drivers, and drivers that came in USB stick (NI System Driver Set 2017. 11-16-2022 10:44 AM. 问题: 4通道的高速数字化仪pxie-5160和pxie-5162在前面板上没有外部触发端子(trig)。我是否需要采集从模拟输入通道的数据. When using multiple PXIe-517x NI Reconfigurable Oscilloscope cards and there is a need to synchronize them, than there are two options for the user: Using the NI-SCOPE Driver with NI-TClk for synchronization implementation - NI-SCOPE Examples. 919 809 5227. he PXIe‑5105 high-density PXI oscilloscope has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. paul. We have 1 NI PXIe-5160 manual available for free PDF download: Calibration Procedure . View online (18 pages) or download PDF (957 KB) National Instruments PXIe-5163, PXIe-5162 User manual • PXIe-5163, PXIe-5162 software PDF manual download and more National Instruments online manualsPXIe-5160/5162 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. This file contains important information about Calibration Executive, including installation instructions, new features, and known issues. PXI oscilloscopes also feature a number of triggering modes, deep onboard. 1 PXI Chassis 2 Ejector Handle in Downward Position 3 Screws 4 NI PXI ModuleBuy 782621-03 - Ni - PXIE-5160 PXI OSCILLOSCOPE, 500 MHZ, 10 BITS, 2. 2 GB/s into or out of the module. Here is a diagram from the Help File (also can be found installed on your system) P2P Streaming Architecture of NI 5160/5162. PXIe-5160/5162 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. Table 3. PXIe, 1. Module. pxie-5160(2 ch) 2(同時サンプリング) pxie-5160(4 ch) 4(同時サンプリング) 入力タイプ 基準化シングルエンド コネクタ bnc インピーダンスおよびカプリング メモ インピーダンスおよびカプリングは、チャンネルごとにソフトウェア で構成できます。 表 1. PXIe, 500 MHz, 2. Raw data from the digitizer were saved as 1D waveforms and then converted to tagged image format (TIF). NI PXIe 5162 NI PXIe 5160 EDITION DATE May 9, 2013 Contact: 866-275-6964 373851C-01 [email protected] device monitor does not recognize/detect anything . Configure the calibrator output impedance. To perform manual adjustment, an external signal is needed that has low jitter and skew. • Ensure that the PXI chassis fan speed is set to HIGH, that the fan filters (if present) are clean, and that the empty slots contain slot blockers and filler panels. 7. 5 GS/s 10 bits, 2/4 channels PXIe-5162 1. Test Equipment National Instruments PXIe-5160 Getting Started Manual. The clean up doesn't seem to be working for large block diagrams. This IVI driver is for use with NI oscilloscopes. 5 GS/s with flexible settings for coupling, voltage range, and filtering. The NI PXIe-5170R and NI PXIe-5171R combine the high performance of NI oscilloscope instruments with the user programmable FPGA of NI. Amazon. Order by Part Number or Request a Quote. From this location the cards within the PXI (e) Chassis can use the signal which comes through the trigger line. 5GS/sec, what steps should I take care and be aware of to handle this high speed ? NI-SCOPE is loaded and recognizes the PXIe-5160. I am used to a Tektronix or LeCroy scope where the math functions are built into the scope. 5 GHz, 10-bit oscilloscope with a sample rate of up to 5 GS/s. NI-SCOPE 4. Re: Change x-axis tick label. *The PXIe 5172 also features a programmable Kintex-7 325T FPGA that can be used for custom acquisition, triggering, signal processing, and data streaming. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2. The PXIe-5163 is a 200 MHz , 1 GS/s oscilloscope. Once data is in MATLAB, you can.